Standalone software
ezIMS
Connecting Ion Mobility with Molecular Insight.
The central concept
One Injection. Two Analytical Dimensions.
ezIMS combines ion mobility spectrometry and mass spectrometry data from the same analytical run. Both dimensions can be processed independently and correlated whenever additional molecular information is needed. The IMS module couples to the GC-MS via a Deans switch; the mass analyser is up to you — quadrupole, TOF or Orbitrap.
- 01
IMS Analysis
- Heatmap visualisation
- Feature detection
- Retention index (RI)
- Reduced ion mobility (K₀)
- 02
MS Analysis
- Mass spectra extraction
- Spectral processing
- Mass spectral library search
- 03Unique to ezIMS
Correlative IMS-MS Analysis
- Linking IMS features with MS spectra
- Retention and mobility combined with spectral evidence
- Supporting compound annotation
Workflow
Two independent workflows, one correlation
IMS and MS each run their own optimised workflow and deliver results on their own. They meet only where it adds information: in the correlative IMS-MS analysis.
Analyze independently. Correlate intelligently. Strengthen identification.
Key capabilities
What ezIMS does
Each capability with the edition it starts in.
GC-IMS heatmap analysis
Retention time against drift time — every signal of the run in one view.
From Essential
Feature detection
Finds the signals in the heatmap and turns them into comparable features.
From Essential
Retention index (RI)
Retention expressed as retention index, for comparison with databases.
From Essential
Reduced ion mobility (K₀)
Drift times expressed as K₀, for comparison across measurements.
From Essential
MS data processing
Extracts and processes the mass spectra recorded in the same run.
From Professional
Mass spectral library search1
Candidates from NIST-compatible libraries, scored by SI and RSI.
From Professional
Correlative IMS-MS analysis
Links IMS features to MS spectra and combines RI, K₀ and spectral evidence.
From Professional
Chemometrics and classification
Explore with PCA, classify with PLS-DA.
From Essential
Machine learning and advanced analytics
Gradient boosting, CNNs, workflow automation and API access.
Enterprise
1 Mass spectral libraries such as NIST, EPA or NIH are not included in the ezIMS licence and require their own licence.
Editions
Choose your depth
Commercial editions are available as an annual subscription. The Community Edition is free for academic research.
Invari8 RI/K₀ Library
Optional add-on
Our curated retention index and reduced ion mobility database, available separately as an add-on with its own licence key.
A closer look
ezIMS in action
Swipe or use the arrows; click an image to view it large.
GC-IMS heatmap with IMS & MS overlay and the mass spectrum of the selected scan1 / 10